Download 2008 ASHRAE Handbook - Heating, Ventilating, and by American Society of Heating PDF

By American Society of Heating

The 2008 ASHRAE instruction manual - HVAC structures and gear discusses quite a few structures and the apparatus (components or assemblies) that contain them, and describes gains and transformations. this knowledge is helping method designers and operators in determining and utilizing apparatus. it's divided into seven sections:

  • Air-Conditioning and Heating structures
  • Air-Handling apparatus and elements
  • Heating apparatus and elements
  • Cooling gear and elements
  • General parts
  • Packaged, Unitary and Split-System gear
  • General
    This name has been lately up to date with 221 Digitized Graphs and a couple of Interactive Tables protecting potency, radiation warmth flux, functionality, warmth loss and lots of different invaluable issues.

    Show description

    Read or Download 2008 ASHRAE Handbook - Heating, Ventilating, and Air-Conditioning Systems and Equipment (I-P Edition) PDF

    Best ventilation & air conditioning books

    Passive and Active Structural Vibration Control in Civil Engineering (CISM International Centre for Mechanical Sciences)

    Base isolation, passive strength dissipation and lively regulate signify 3 leading edge applied sciences for defense of constructions less than environmental quite a bit. more and more, they're being utilized to the layout of recent constructions or to the retrofit of present buildings opposed to wind, earthquakes and different exterior quite a bit.

    Environmental Wind Engineering and Design of Wind Energy Structures

    The ebook offers a state of the art in environmental aerodynamics and the structural layout of wind strength help buildings, rather from a latest computational point of view. Examples contain real-life purposes facing pollutant dispersion within the construction surroundings, pedestrian-level winds, convenience degrees, appropriate laws and remedial measures.

    Stability Analysis and Design of Structures

    Speedy advances in analytical tools and computing allow engineers to use stability/stiffness ways to more and more complicated real-life circumstances. This complex and graduate-level textual content and self-tutorial teaches readers to appreciate and to use analytical layout rules around the breadth of the engineering sciences.

    Plastic Methods for Steel and Concrete Structures

    This can be a thoroughly revised, up-to-date and reset version of the textual content that seemed with an analogous identify throughout the Eighties. It covers the necessities of the latest layout criteria (BS5950, BS8110 and the Eurocodes) and may entice undergraduate and postgraduate scholars of civil and structural engineering and to working towards engineers.

    Additional resources for 2008 ASHRAE Handbook - Heating, Ventilating, and Air-Conditioning Systems and Equipment (I-P Edition)

    Example text

    8 Chemical Humidification Fig. 8 Chemical Dehumidification Steam Injection Humidification AIR-HANDLING UNIT COMPONENTS Fig. 7 Steam Injection Humidification air. Similarly, air will also be dehumidified if a fluid with a temperature below the airstream dew point is sprayed into the airstream (see the section on Air Washers in Chapter 40). The process is identical to that shown in Figure 2, except that the moisture condensed from the airstream condenses on, and dissolves in, the spray droplets instead of on the solid coil surface.

    Failure of an air-handling unit affects only the part of the building served by that one unit. Fans Both packaged and built-up air-handling units can use any type of fan. Centrifugal fans may be forward-curved, backward-inclined, or airfoil, and single-width/single-inlet (SWSI) or double-width/ double-inlet (DWDI). Many packaged air-handlers feature a single fan, but it is possible for packaged and custom air handlers to use multiple DWDI centrifugal fans on a common shaft with a single drive motor.

    Coil freezing can be a serious problem with chilled-water coils. Full-flow circulation of chilled water during freezing weather, or even reduced flow with a small recirculating pump, minimizes coil freezing and eliminates stratification. Further, continuous full-flow circulation can provide a source of off-season chilled water in airand-water systems. Antifreeze solutions or complete coil draining also prevent coil freezing. However, because it is difficult (if not impossible) to drain most cooling coils completely, caution should be used if this option is considered.

    Download PDF sample

    Rated 4.59 of 5 – based on 19 votes